Data Logger and TRAC4 Software - Updated in 2011 |
The Latest in Data Logging for CP Applications |
|
|
![]() |
|
![]() |
|
|
Features:
|
Kit Includes:
|
Electrical & Mechanical Specifications |
|
| INPUTS | |
| Analog | 4 Analog Channels |
| Input Voltage Range | +/-5v ch 1 &2, 150VRMS ch 3, +/- 100v TrueView |
| Resolution | 1mV ch 1 &2 |
| Input Impedance | 200+ Meg Ohms |
| Sampling Frequency | Fast as 1 KHz, Slow as 1/99 min. (All channels) |
| DATA STORAGE | 1,000,000 samples (with Time & Date stamp) |
Recording Duration |
0.001 seconds to years |
| Data Memory Battery Life (backup) | 10 years |
Power Supply |
|
Voltage |
9v battery (alkaline -type) |
| Current | 43mV |
| Standby | 1.7mV |
| Battery Life | up to one (1) Month, (4) 9v Alkaline, 1/min Sampling rate |
| Operating Temperature | -15 to 55 degrees Celsius |
| Storage Temperature | -15 to 55 degrees Celsius |
| Communication | USB Interface |
| Dimensions - Instrument | 1.5" x 1.5" x 10.25" (38.1 mm x 38.1 mm x 260.35 mm) |
| Weight - Instrument | 10 oz. (283g) |