-Instructions for SC-4-

Silver Chloride Reference Electrode

T&R Product Instructions     Reference Electrodes
 

IMPORTANT NOTE: Do not use this instrument in an explosive environment.

Model SC-4

Land / Sea Configurations

 

This manual contains operating, maintenance and storage instructions for Tinker & Rasor’s Model SC-4 AgAg/CI Reference Electrode “Land” use.

This kit includes:

1 - Ag/CI Element with end cap

1 - Ceramic Tip Assembly (Land)

1 - Tube Body with holes (Sea)

1 - Tube Body w/o holes (Land)

1 - End Plug (Storage)

1 - Brass Weight (“B”) (Sea)

1 - 4 oz. Solution (Land & Storage)

1 - Waterproof Adapter w/lead (Sea)

2 - Instruction Manuals (Land & Sea)

1 - Carrying Case w/inserts

 

SEE PARTS LIST DRAWING

 Optional Accessories

Tinker & Rasor Models

  • CPV-2 Voltmeter Analog
  • CPV-4 Voltmeter Digita

 REQUIREMENTS

  • 1.       Voltmeter – any high input resistance 20 Megaohm or greater - see “Optional Accessories”.
  • 2.       Test Lead – 18 Ga. stranded wire, 8 ft supplied. (longer test lead available upon request)
  • 3.       Electrolyte – 4 oz. “Ocean Water” supplied  - Potassium Chloride  35:1 mix is okay for storage - see “Maintenance”

 PREPARATION & ASSEMBLY

  • 1.       Clean Ag/CI element per instruction under “Maintenance” section.
  • 2.       Screw end cap with Ag/CI into solid tube (part #118-061) and tighten by hand.
  • 3.       Fill tube with “Ocean Water” (part #049-016).
  • 4.       Screw ceramic tip assembly into tube and tighten by hand - check “O” rings for leaks.
  • 5.       Attach 18 Ga. test lead to top of electrode using knurled nut (supplied).
  • 6.       Attach test lead to voltmeter. *

Note:

      A.  Ceramic tip assembly should soak in electrolyte (Ocean Water) until thoroughly saturated.

      B.  Ag/CI element must be cleaned, and then soaked in electrolyte at least 15 minutes prior to first use.

*Any quality high resistance meter - 20 megohm or greater such as Tinker & Rasor Model CPV-4 Digital Voltmeter.

OPERATIONS

  • 1.       Press the electrodes’ ceramic tip into the soil.
  • 2.       Submerge the tip or the entire electrode into electrolyte.
  • 3.       Place a sponge soaked in electrolyte under the ceramic tip for dry soil conditions.
  • 4.       The ceramic tip assembly must be soaked in electrolyte until thoroughly saturated.

 MAINTENANCE & STORAGE

 Before Use: 

  • 1.       The Ag/CI element must be cleaned in distilled water or mild detergent and rinsed in distilled water prior to use.
  • 2.       Do not touch Ag/CI element after cleaning.
  • 3.       The Ag/CI element should soak in electrolyte for at least 15 minutes before use to stabilize readings.

 After Use:

  • 1.       To ensure proper readings we recommend the Ag/CI element and the ceramic tip assembly be kept moist during storage.  A solid body tube and protective cover are enclosed for this sorage period as well as for use in soil readings.
  • 2.       For long-term storage, disassemble or for use after element and ceramic tip have been allowed to dry follow instructions above “Before Use”.

STANDARD POTENTIALS to HYDROGEN

 SPECIFICATIONS - LAND

 Length                       (125.48 mm)    4.94 In.

Diameter  (Max.)         (  33.27 mm)    1.31 In.

Ceramic                     (  28.49 mm)    1.12 In.

Threads                      1/4-20

Temperature Range     (0-900 C)           0-194o F

Shipping Weight         (1.9 kg)            3.5 lbs.

 

INTRODUCTION

 This manual contains operating, maintenance and storage instructions for Tinker & Rasor’s Model SC-4 AgAg/CI Reference Electrode “Sea” use.

This kit includes

1 - Ag/CI Element w/end cap

1 - Ceramic Tip Assembly                       ( Land)

1 - Tube Body with holes                        (Sea)

1 - Tube Body w/o holes                         (Land & Storage)

1 - End Plug                                          (Storage)

1 - Brass Weight                                    (Sea)

1 - 4 oz. Solution                                   (Land & Storage)

1 - Waterproof Adapter w/lead                 (Sea)

2 - Instruction Manuals                           (Land & Storage)

1 - Carrying Case w/inserts

SEE PARTS LIST DRAWING

 Optional Accessories:

Tinker & Rasor Models

 

  • CPV-2 Voltmeter Analog
  • CPV-4 Voltmeter Digital
 

REQUIREMENTS

  • 1.       Voltmeter – any high input resistance 20 Megohm or greater - see “Optional Accessories”.
  • 2.       Test Lead – 18 Ga. stranded wire, 8 ft. supplied. (longer test lead available upon request)
  • 3.       Electrolyte 4 oz. – “Ocean Water” supplied - Potassium Chloride 35:1 mix is okay for storage - see “Maintenance”.

PREPARATION & ASSEMBLY

  • 1.       Clean Ag/CI element per instruction under “Maintenance” section.
  • 2.       Screw end cap with Ag/CI element into tube with holes (part #118-060) and tighten by hand.
  • 3.       Screw brass weight (“B”) into tube and tighten by hand.
  • 4.       Attach 18 Ga. test lead into waterproof adapter (part #009-010) - see W-7 instructions.
  • 5.       Remove knurled nut from top end cap and save.
  • 6.       Screw top of electrode into W-7 Waterproof Adapter and tighten by hand.
  • 7.       Attach test lead wire to voltmeter.
  • 8.       Lower entire electrode into electrolyte and allow to soak for 15 minutes to stabilize readings.

OPERATIONS

  • 1.       Submerge the tip or the entire electrode into electrolyte.

Note:

 Readings should be taken as close to the structure as possible to minimize I.R. drop.  Avoid surface contaminates.

MAINTENANCE & STORAGE

Before Use: 

  • 1.       The Ag/CI element must be cleaned in distilled water or mild detergent and rinsed in distilled water prior to use.
  • 2.       Do not touch Ag/CI element after cleaning.
  • 3.       The Ag/CI element should soak in electrolyte for at least 15 minutes before use to stabilize readings.

After Use:

  • 1.       To ensure proper readings we recommend the Ag/CI element and the ceramic tip assembly be kept moist during storage.  A solid body tube and end plug are included for this storage period as well as for use in soil readings.
  • 2.       For long-term storage, disassemble or for use after element and ceramic tip have been allowed to dry follow instructions above “Before Use”.

SPECIFICATIONS  -  SEA

 Length                          (125.48 mm)      4.94 In.

Diameter (Max.)             ( 33.27 mm)       1.31 In.

Ceramic                        ( 28.49 mm)       1.12 In.

Threads                         1/4-20

Temperature Range

                                    (0-900C)             0-1940 F

Shipping Weight            (  1.9 kg)           3.5 lbs.

012-155

All instruments being returned for repair should be sent PREPAID to either address below: 

Ship Via Courrier (UPS, FedEx, DHL, etc)

Tinker & Rasor
ATTN: Repairs
791 S. Waterman Ave.
San Bernardino, CA 92408

Ship Via US Postal Mail

Tinker & Rasor
ATTN: Repairs
PO BOX 6890
San Bernardino, CA 92412-6890

Include with shipment information the nature of the problem, purchase order, serial number
and return delivery address, phone and fax numbers. Immediate service is guaranteed!

T&R Product Instructions     Pipe & Cable Locating