Return to Homepage
-Instructions for PRM Peak Reading Voltmeter-

T&R Product Instructions     PRM Peak Reading Voltmeter





 

IMPORTANT NOTE: Do not use this instrument in an explosive environment.
The Tinker & Rasor Model PRM Peak Reading Voltmeter is designed to measure the peak value of high voltage pulses within its scale range, with a maximum capacity of 40 kilovolts. Voltage measurements can be made of peak values with a rise time of less than one millionth of a second. 
 
 

1. MODEL PRM INCLUDES

  • 1 -Peak Reading Voltmeter 
  • 1 - Ground Cable 
  • 1 - High Voltage Cable 
  • 1 - Carrying Case and
  • 6 - "AA" batteries. 
 
 
2. UNPACKING

Check all components against the packing list. If damage has occurred in shipment file a claim with the carrier immediately. If it is necessary to contact your supplier or the manufacturer concerning damaged or missing items be sure to include all the information such as serial number, purchase order number and invoice number. This will assure you of obtaining proper and expeditious service. 
 
 

3. DESCRIPTION

The Model PRM is a portable, battery powered, voltmeter capable of accurately measuring pulse type high voltages such as those generated by the "so called" spark type Holiday Detector and clearly recognizing the values of either polarity. Equipped with large five digit liquid crystal display and single control switch for selecting proper polarity and testing of self contained power supply. The cables supplied with the meter are well insulated for the proper use in measuring high voltages, however, care should be exercised not to physically hold or touch these cables or connections while the high voltage potential is present. Also, cables should not rest on each other or place on conductive surface while making voltage measurements. 

Always observe proper safety precautions when operating high voltage equipment. 
 
 

4. VOLTAGE TESTING PROCEDURES

A. Connect one of the two high tension cables, supplied with the voltmeter, between the dome
     top terminal of voltmeter and the high voltage output of the Holiday Detector. 

B. Connect the other high tension cable between the ground post of the voltmeter and the 
     ground terminal of the Holiday Detector. 

C. After properly connecting cables (see note below) turn Holiday Detector "ON". 

D. Turn the control knob on the voltmeter to the positive (+) position and observe the meter 
     reading if the meter reading does not closely correspond to the factory marking of the 
     Holiday Detector turn the control knob to the negative (-) position. The meter reading must 
     be within 10 percent of the factory markings on the Holiday Detector in one or the other 
     polarities, otherwise there is a fault in one or both instruments. 

   Note: It may be necessary to use the cables supplied with the Holiday Detector in 
   conjunction with those supplied with the Voltmeter because the terminals vary on 
   different Holiday Detectors.

     For example: Connections can be made directly to the ground wire and high voltage cable
     of the Holiday Detector to facilitate proper electrical connections. 
 
 

5. BATTERY TEST

Turn control knob to "Bat." position. Battery should read minimum of 6.0 volts. Replace if needed with fresh 6 each 1-1/2 volt "AA" Cell Batteries. 

Note: Do not store Voltmeter with batteries in place for long periods of time. 
 
 

6. MAINTENANCE & SERVICE

Always store Voltmeter in Carrying Case. Do not expose to excessive moisture (keep dry) and clean. For factory service, send complete instrument freight prepaid to: 
 
 

7. SHIPPING INSTRUCTIONS 

All instruments being returned for repair should be sent PREPAID to either address below: 

Tinker & Rasor
417 Agostino Road
P.O. Box 281
San Gabriel, CA 91778
Include with shipment information the nature of the problem, purchase order, serial number and return delivery address. Immediate service is guaranteed!

 

T&R Product Instructions     PRM Peak Reading Voltmeter