-Instructionsfor CS-1 Mag Anode Simulator-
(for cathodicprotection testing)

T&RProduct Instructions     Current& Power Supply

 

CS-1 Mag Anode Simulator

The Model CS-1 isa portable, adjustable current supply capable of delivering up to 1.5 ampsof DC current depending on load conditions. The output voltage is fixedat 1.7 volts DC making the CS-1 ideal for use as a magnesium anode simulator.The CS-1 has a digital display to show the amount of current impressedand to check the internal DC battery level. 

For convenience inthe field, the CS-1 Mag Anode Simulator uses 4 replaceable “D” cell batteriesto provide current and a replaceable 9 volt battery for the meter display.For best performance Tinker & Rasor recommends the use of alkalinebatteries.

CONTROLPANEL

On / OFF – Used to turn the CS-1 current and panel meteron and off.

AMPS / VOLTS – To select value to be shown on the digital display. Select AMPS to display current and VOLTS to display the battery level.

NOTE: The output of the CS-1 is regulated at 1.7 volts DC. The "VOLTS" position of the selector knob indicates the status of the internal "D" cell batteries. Replace "D" cell batteries when the display indicates 1.0 volts or less

CURRENT ADJUST – Use to adjust the current applied to the pipe and / or structure.

DIRECTIONS
Using the supplied cables, connect the test lead from the positive (Red) connector on the side of the CS-1 to the pipe or structure under test. Connect the negative (Black) connector from the side of the CS-1 to a good earth ground.
Turn the CS-1 on.
Turn the AMPS / VOLTS switch to AMPS.
The current can now be adjusted to the desired level. The current output can be read on the digital display. Once the CS-1 is satisfactorily connected to the pipe, a pipe-to-soil potential can be conducted to view the results of the connection.
The CS-1 simulates one (1) magnesium anode on the system. It should be possible, based upon the results of the pipe-to-soil survey to extrapolate how multiple magnesium anodes would affect the system.

When not in use the test leads can be stored in the CS-1 case. To replace the batteries, remove the two Phillips screws located on the control panel of the CS-1. Lift the control panel from the case to access the batteries.

WARRANTY

Ninety day warrantyon Parts and Labor.

TECHNICALSUPPORT

If you require assistancewith the CS-1 or any Tinker & Rasor product please call 
(323)283-3134 Monday- Friday 6:00 a.m. to 4:00 p.m. pacific time or e-mailTinker & Rasor.

REPAIR

Tinker & Rasorstrongly suggests Tinker & Rasor perform all repairs. Tinker &Rasor must perform all warranty work. Many of the CS-1 components may notbe readily available to outside repair agencies. All repairs are turnedaround in 24 hours.  See below.

SHIPPINGINSTRUCTIONS 

All instruments being returned for repair should be sent PREPAID to either address below: 

Ship Via Courrier (UPS, FedEx, DHL, etc)

Tinker & Rasor
ATTN: Repairs
791 S. Waterman Ave.
San Bernardino, CA 92408

Ship Via US Postal Mail

Tinker & Rasor
ATTN: Repairs
PO BOX 6890
San Bernardino, CA 92412-6890

Include with shipment information the nature of the problem, purchase order, serial number
and return delivery address, phone and fax numbers. Immediate service is guaranteed!

T&RProduct Instructions     Current& Power Supply